COMPRESSOR ROD DROP INDICATOR
The Exline Compressor Rod Drop Indicator is installed directly beneath the compressor rod to detect wear.

If wear occurs on the piston, piston riders, or cylinders, the compressor rod drops and makes contact with the indicator. This contact creates a friction temperature which melts the fuse-metal plug in the device. A pressure drop in the pneumatic control system results. This pressure drop can be used to shut down the equipment or sound an alarm. A flat end indicator can be used to detect excessive end play in rotating equipment.

• Total Reliability
• No Maintenance
• No Calibration
• No Deterioration
• Wide Range of Temperatures
• Reusable
• Device can be reloaded quickly and easily at our factory
Standard Sizes in Stock
Rod Diameter
Part No.
Vented CRD
Flat End
300500
350396
 1.5"
300503
350535
2.0"
300504
350388
2.5"
300505
350536
3.0"
300506
350387
3.5"
300507
350355
4.0"
300508
350254
4.5"
300509
350272
5.0"
300510
350389
5.5"
300511
350538

Special sizes available. Allow for additional delivery time.
Metric sizes available upon request.

How to Order

Determine rod diameter and temperature desired Show part # and temperature. Example:
3" Dia. Rod - 178°F #300506 - 178°F


Available Fuse-Metal
Melting Temps
117°F
162°F
217°F
281°F
361°F
136°F
178°F
228°F
291°F
374°F
142°F
198°F
243°F
310°F
390°F
150°F
205°F
255°F
349°F

When ordering, specify one of the temperatures listed.

Details of Installation

Compressor Rod Drop Indicator:
Using the packing case nuts as mounting points, a bracket can be fabricated to support the CRD directly under the compressor rod. Two holes are drilled and tapped in the surface of the bracket to attach the device. A shim stock (for example .010) is inserted between the surface of the compressor rod and curved surface of the device. The device is positioned firmly against the shim stock and bolts are tightened. This permanently positions the CRD in place. The shim is removed and the device is piped to the control header. The flat end device can be used to detect excessive end play in rotating equipment.

Vented Compressor Rod Drop Indicator:
Install as described above. Tube supply “SUP” side to air header. Tube vent side “VENT” to atmosphere or appropriate area.

*Not recommended for use with units that operate with synthetic oils.