The Exline Trip Switch can be used to sound an alarm or initiate shutdown. It is available for initial installation and as a replacement for existing trip valve installations. Normally no mounting or bracket changes are required on replacements, and the switch will work with any make or model tripping device. Superior design virtually eliminates maintenance.


Micro Switch Electrical Characteristics
Electrical Rating
28VDC/115VAC, 400 Hz
Resistive
5 Amps
Inductive
3 Amps
Dielectric Withstanding Voltage
1000V rms at sea level for 1 minute or 1250V rms for 1 second with maximum leakage current 0.5 milliamperes.
Contact Arrangement
SPDT
Temperature Range
-65° F to 660° F (-54°C to 349°C) Intermittent
Shock
100g for 6 ± 1 ms
Vibration
10 - 2000 Hz ± 20g peak
Ambient Pressure
High Vacuum (negative) to 50 psi (positive) 3.5 atmospheres
Military Specification
MIL-PRF-8805
Applications
Exline Trip Switches are used to protect moving, rotating, or oscillating components fitted with Exline Temperature Sensors. When tripped by sensors, these switches can automatically shut down equipment or trigger an alarm.

When used in engines or compressors, the unique body design permits crankcase oil “flow-through” to minimize carbon and varnish buildup in the piston area. In hazardous locations, the Trip Switch must only be used with intrinsically safe controls.

To Order
The Trip Switch can handle up to a 15 amp load and comes “normally closed.” Specify if you want a “normally open” configuration. TFE-coated lead wires are either encased in a flexible braided stainless steel overlay. Determine the upper temperature limit desired. Then select an appropriate Striker Sensor. See “Striker Sensor” for standard models and temperatures.
 
To order the Trip Switch, specify one of the following:
Part No. 303164 Trip Switch with braid protected TFE-coated wires.
Refer to Striker Sensor
Easy Installation
The Trip Switch mounts directly in line with an Exline Striker Sensor, as in the illustration. Proper brackets, fittings, and other hardware can be supplied by Exline for your particular installation. We can also provide and install complete systems, including monitoring panels. Contact your Exline representative for more information.