ELECTRONIC
TRIP SWITCH
The
Exline Trip Switch can be used to sound an alarm or
initiate shutdown. It is available for initial installation
and as a replacement for existing trip valve installations.
Normally no mounting or bracket changes are required
on replacements, and the switch will work with any make
or model tripping device. Superior design virtually
eliminates maintenance.
|
| Micro
Switch Electrical Characteristics
|
| Electrical
Rating |
28VDC/115VAC,
400 Hz |
| Resistive |
5
Amps |
| Inductive |
3
Amps |
| Dielectric
Withstanding Voltage |
1000V
rms at sea level for 1 minute or 1250V rms
for 1 second with maximum leakage current
0.5 milliamperes. |
| Contact
Arrangement |
SPDT |
| Temperature
Range |
-65° F
to 660° F (-54°C to 349°C) Intermittent |
Shock |
100g
for 6 ± 1 ms |
Vibration |
10
- 2000 Hz ± 20g peak |
Ambient
Pressure |
High
Vacuum (negative) to 50 psi (positive) 3.5
atmospheres |
Military
Specification |
MIL-PRF-8805 |
|
| Applications
|
| Exline
Trip Switches are used to protect moving,
rotating, or oscillating components fitted
with Exline Temperature Sensors. When tripped
by sensors, these switches can automatically
shut down equipment or trigger an alarm.
When used in engines or compressors, the
unique body design permits crankcase oil
“flow-through” to minimize carbon
and varnish buildup in the piston area.
In hazardous locations, the Trip Switch
must only be used with intrinsically safe
controls. |
| To Order
|
| The
Trip Switch can handle up to a 15 amp load
and comes “normally closed.”
Specify if you want a “normally open”
configuration. TFE-coated lead wires are
either encased in a flexible braided stainless
steel overlay. Determine the upper temperature
limit desired. Then select an appropriate
Striker Sensor. See “Striker Sensor”
for standard models and temperatures. |
| |
To
order the Trip Switch, specify one of the
following:
Part No. 303164 Trip Switch with braid protected
TFE-coated wires.
Refer to Striker Sensor |
|
|
Easy Installation
The Trip Switch mounts directly in line
with an Exline Striker Sensor, as in the illustration.
Proper brackets, fittings, and other hardware can be supplied
by Exline for your particular installation. We can also
provide and install complete systems, including monitoring
panels. Contact your Exline representative for more information.
|